8-position intelligent PDU socket, C13, C20
Detail Information
| Working Voltage: | 220V-110V | ||
|---|---|---|---|
| Current: | 5ma | ||
Key Feature:
Color LCD display
Provide real-time power monitoring
Able to remotely turn on/off a single socket
Users can customize alarm thresholds
Socket metering function provided by PDU
Users can customize alarm thresholds
Advanced switching function
Provide isolated CANbus, RS485 serial networking mode
With socket group management function
Socket sorting delay to avoid circuit overload, and can customize the time



Specification
1. The double-precision high-energy calculation method can provide very accurate power metering and power factor data for a single socket.
2. Color LCD display
The color LCD display is used to intuitively display information such as voltage, current, power factor, power, IP address, temperature and humidity, CAN/485 hardware address, etc.
3. Provide real-time power monitoring
The efficient data processing method can not only provide real-time data such as input current, voltage, power, power factor, power, frequency, etc., but also provide the power output of each socket with the PDU with each socket detection function, and can display the current, power factor and power of each socket in real time. Provide the function of curve image display.
4. Able to remotely turn on/off a single socket
The PDU with each bit control function can control each socket through network protocols such as HTTP, SNMP, SSH, etc. to realize remote control function. At the same time, various protocols can provide encrypted SSL to make remote control more secure and reliable.
5. Socket metering function provided by PDU
It provides users with a basis for accurate calculation of PUE, and can plan and optimize the energy consumption of the data center, thereby providing data center managers with a basis for reducing costs for load balancing and setting up IT environment.
6. Users can customize alarm thresholds, and can warn of potential circuit overloads through real-time local and remote alarms, thereby reducing risks.
7. Advanced switching function, which can realize user-defined logic control, can independently realize the switching action and schedule of each socket position, and can take intelligent actions according to environmental changes.
Users can control the PDU output switch according to the current threshold and temperature threshold, and give multiple alarm prompts at the same time. The sockets have parameter copying function. After setting the parameters of one socket, they can be quickly copied to other sockets. At the same time, the PDU with socket management, each socket can switch the socket according to the time or time period set by the user, and has 20 user-defined time or time period editing functions to meet the user’s complex logic control needs.
8. Socket sorting delay to avoid circuit overload, and can customize the time
When switching sockets or powering on, the power-on time interval between sockets can be flexibly set, which is conducive to stable operation of the load and avoid surges.
9. With socket group management function
PDU with single socket management, users can customize socket grouping, and flexible socket grouping is conducive to user classification management of sockets. At the same time, the hardware is also independently divided into 3 groups, each with 8 sockets. The three-phase PDU also achieves electrical isolation for every 8 sockets.
10. Users can access and configure multiple access control methods through a secure Web, SNMP, SSH or Telnet interface, which is easy to operate and integrate.
11. Provide isolated 2-way temperature/humidity sensor, 3-way input and 1-way output port
12. Provide isolated CANbus, RS485 serial networking mode
This PDU not only provides the common SNMP management function in data centers, but also can collect data and control equipment through serial methods such as CAN bus and RS485. In small and medium-sized data centers or environments without network conditions, this PDU can provide multiple integration methods to facilitate user secondary development.